The PDS863 Single Flange Level Transmitter is a smart flanged level transmitter designed for continuous liquid level measurement in tanks, vessels, reactors, and process equipment. It measures liquid level by sensing the hydrostatic pressure acting on the flange-mounted diaphragm and converts it into 4–20 mA DC with HART communication, or optional PROFIBUS PA and FOUNDATION Fieldbus FF output signals.
With ±0.04% FS accuracy, 30:1 rangeability, long-term stability of ±0.1% FS over 10 years, intelligent diagnostics, simulation functions, and multiple corrosion-resistant material options, the PDS863 is suitable for industrial tank level measurement in chemical, petrochemical, power generation, water treatment, and process automation applications.
The PDS863 single flange level transmitter is used for measuring liquid level in tanks and vessels by detecting the pressure generated by the liquid column. It is usually installed on the side flange or lower nozzle of a tank, vessel, reactor, separator, or storage container.
This structure uses a flange-mounted diaphragm seal in direct contact with the process liquid. The diaphragm transfers the process pressure to the transmitter sensor, and the transmitter converts the measured signal into a standard output for PLC, DCS, or fieldbus systems.
The PDS863 supports 4–20 mA DC with HART communication, PROFIBUS PA, and FOUNDATION Fieldbus FF outputs. Through a HART communicator, fieldbus system, or compatible communication device, users can perform remote setting, monitoring, diagnostics, simulation, and maintenance.
For open tanks or vessels where the top pressure is atmospheric or clearly defined, a single flange level transmitter is often a practical and economical level measurement solution.
The PDS863 single flange level transmitter can be selected with different output signals according to the automation system.
| Output / Communication | Description |
|---|---|
| 4–20 mA DC + HART | Standard analog output with HART digital communication |
| PROFIBUS PA | Digital fieldbus communication for process automation systems |
| FOUNDATION Fieldbus FF | Fieldbus communication for advanced field instrument networks |
For most industrial tank level measurement applications, 4–20 mA with HART is widely used because it is compatible with many PLC and DCS systems while still supporting smart configuration, diagnostics, and loop checking.
The single flange structure allows the transmitter to be mounted directly on the tank or vessel flange. It is suitable for liquid level applications where ordinary threaded pressure connections may be too small, easy to block, or unsuitable for corrosive and viscous media.
The PDS863 provides ±0.04% FS accuracy, supporting stable level measurement in storage tanks, process vessels, reactors, separators, and industrial level control loops.
The maximum rangeability of 30:1 provides flexibility for different tank heights and calibrated level spans.
The transmitter offers long-term stability of ±0.1% FS over 10 years, helping reduce recalibration frequency and maintenance workload during continuous operation.
The PDS863 supports intelligent diagnostic and simulation functions. These functions help users check transmitter status, verify output signals, identify abnormal conditions, and simplify commissioning or troubleshooting.
Configuration can be performed through a HART communicator, PROFIBUS PA system, FOUNDATION Fieldbus system, or compatible communication device depending on the selected output.
Different diaphragm and wetted material options can be selected for different liquids. For corrosive, viscous, crystallizing, or dirty media, material and diaphragm seal structure should be confirmed carefully.
| Item | Specification |
|---|---|
| Product Name | PDS863 Single Flange Level Transmitter |
| Product Type | Smart Single Flange Level Transmitter |
| Measurement Type | Liquid Level Measurement |
| Measured Medium | Liquid |
| Output Signal | 4–20 mA DC + HART, PROFIBUS PA, FOUNDATION Fieldbus FF |
| Accuracy | ±0.04% FS |
| Maximum Rangeability | 30:1 |
| Long-Term Stability | ±0.1% FS / 10 years |
| Measuring Range | 0 to 10 MPa |
| Configuration | HART communicator / fieldbus communication device |
| Main Functions | Level measurement, signal output, remote setting, monitoring, diagnostics, simulation |
| Typical Installation | Tank side flange / vessel flange / process equipment flange |
The PDS863 single flange level transmitter measures liquid level based on the hydrostatic pressure generated by the liquid column.
For an open tank, the pressure at the flange connection is mainly determined by:
As the liquid level rises, the pressure acting on the diaphragm increases. As the liquid level falls, the pressure decreases. The transmitter converts this pressure change into a proportional output signal.
In simple terms:
Liquid Level → Hydrostatic Pressure → Diaphragm Seal → Sensor Signal → 4–20 mA / HART / Fieldbus Output
For closed or pressurized tanks, the vapor space pressure may affect the level measurement. In that case, a dual flange differential pressure level transmitter is usually more suitable because it can compensate for the top pressure of the vessel.
Used for liquid level monitoring in chemical storage tanks, reactors, separators, dosing tanks, process vessels, and intermediate tanks. For corrosive media, diaphragm material and flange material should be selected according to chemical compatibility.
Suitable for open tanks, atmospheric storage vessels, water tanks, utility tanks, and process containers where the reference pressure condition is stable and does not require top pressure compensation.
Used for level measurement in water tanks, treatment tanks, filtration systems, dosing tanks, storage vessels, and industrial utility liquid systems.
Applied in condensate tanks, feedwater tanks, chemical dosing tanks, cooling water systems, and other liquid storage or process vessels in power plants.
Used for separators, storage tanks, process vessels, fuel tanks, and auxiliary liquid systems where stable level measurement is required.
With a suitable diaphragm seal and flange size, the PDS863 can be used for certain viscous, dirty, or sediment-containing liquids where ordinary threaded pressure ports may be more likely to block.
Suitable for PLC/DCS systems requiring 4–20 mA HART, PROFIBUS PA, or FOUNDATION Fieldbus FF signals for tank level monitoring and process control.
When selecting a PDS863 single flange level transmitter, the following details should be confirmed:
Depending on site conditions, the PDS863 single flange level transmitter may be used with different installation accessories:
For viscous, crystallizing, dirty, corrosive, or high-temperature liquids, accessories such as flushing rings, flanged reducers, and suitable gaskets can improve installation reliability and maintenance convenience.
Typical installation:
Tank Flange → Gasket → PDS863 Single Flange Level Transmitter
If a flushing ring is used:
Tank Flange → Gasket → Flushing Ring → Gasket → PDS863 Single Flange Level Transmitter
The PDS863 single flange level transmitter is suitable for many liquid level applications, but it is not always the best choice for every tank.
| Item | Single Flange Level Transmitter | Dual Flange DP Level Transmitter |
|---|---|---|
| Typical Tank Type | Open tank or simple vessel | Closed or pressurized tank |
| Process Connection | One flange connection | Two flange connections |
| Top Pressure Compensation | Usually not included | Can compensate vessel top pressure |
| Structure | Simpler and more economical | More suitable for complex level measurement |
| Typical Use | Atmospheric tank level | Pressurized vessel level |
For closed tanks, pressurized vessels, vacuum vessels, or applications where vapor pressure changes significantly, a dual flange differential pressure level transmitter is often more appropriate.
SIYelectric supplies PDS863 single flange level transmitters for industrial projects, replacement orders, and process instrumentation procurement. We can help check model codes, review datasheets, confirm technical specifications, match installation accessories, and prepare quotations based on actual operating conditions.
For accurate quotation, please provide:
SIYelectric can also support related level transmitter accessories such as flushing rings, mating flanges, PTFE gaskets, spiral wound gaskets, flanged reducers, mounting brackets, explosion-proof cable glands, valves, tubing, and fittings.
Available documents may include technical datasheet, certificate of conformity, inspection report, packing list, and commercial invoice, depending on the project and order requirements.
Request Your Custom Solution & Factory Price
*We respect your privacy. Your information is used for technical quotation purposes only and will never be shared.
We use cookies to improve your experience and analyze site traffic. Choose which cookies you allow.
Required for the website to function. Cannot be disabled.
Help us understand how visitors interact with the website.
Used to deliver relevant advertisements and track campaigns.
Remember your settings and preferences for a better experience.