pressure transmitter shop

Differential pressure Deltabar FMD77

shop

  • Deltabar_FMD77_PP1
  • Deltabar_FMD77_PP1
  • Deltabar_FMD77_PP2
  • Deltabar_FMD77_PP3
  • Deltabar_FMD77_PP4
  • Deltabar_FMD77_PP5

Differential pressure Deltabar FMD77

Differential pressure Deltabar FMD77 – Differential pressure transmitter with one diaphragm seal for level measurement

 

Facebook
Twitter
LinkedIn

Specifications:

Measuring PrincipleDifferential pressure
CharacteristicDigital transmitter with metallic measuring diaphragms, one side with diaphragm seal; Modular transmitter; Long-term stability; Secondary process barrier; enhanced saftey via self diagnostic functions
Supply Voltage4...20mA HART: 10,5...45V DC (Non Ex); Ex ia: 10,5...30V DC; PROFIBUS PA: 9...32 V DC (Non Ex); FOUNDATION Fieldbus: 9...32 V DC (Non Ex)
Reference Accuracy0,075% + influence of diaphragm seal
Long Term Stability0.08 % of URL/ year; 0.14 % of URL/ 5 years; 0.27 % of URL/ 10 years
Process Temperature-40°C...400°C (-40°F...752°F)
Ambient Temperature-50°C...85°C (-58°F...185°F)
Measuring Cell100 mbar...16 bar (40 inH20...240 psi)
Smallest Calibratable Span5 mbar (0.075 psi)
Vacuum Resistance50 mbar (0.73 psi)
Max. Turn Down100:1
Max. Overpressure Limit160 bar (2400 psi)
Process ConnectionLow pressure side: 1/4-18NPT; RC1/4"; High pressure side: Flanges (DIN, ASME, JIS)
Material Process Membrane316L, AlloyC, Tantal, Gold-Rhodium, PTFE
Material GasketNone, diaphragm seal welded
Fill FluidSilicone oil, Inert oil, Vegetable oil, Low- temperature oil, High- temperature oil
Material Housing316L, Die-cast aluminum
Communication4...20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety ApprovalsSIL
Design ApprovalsNACE MR0175; EN10204-3.1
SpecialitiesDiagnostic functions
SuccessorPMD78B

 

 

Field of application

The Deltabar FMD77 differential pressure transmitter with metal sensor uses a one-sided diaphragm seal or diaphragm seals on both sides with a capillary on the low pressure side. Typically used in the process industry for continuous level measurement in liquids. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.

For level, volume or mass measurement in liquids.

  • Process connections: Threads and flanges

  • Temperature: -70 to +400°C (-94 to +752°F)

  • Measuring ranges: +100mbar to +16bar (+1.5 to +240psi)

  • Accuracy: ±0.075%

  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL

 

Benefits

  • Large variety of different process connections and membrane materials

  • Highest safety due to gas-tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

  • New TempC Membrane minimizes influences of ambient and process temperature fluctuations

  • Easy menu-guided commissioning via local display, 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Seamless and independent system integration (HART/PA/FF)

 

Categories

Request Your Custom Solution & Factory Price

Contact Form Demo

*We respect your privacy. Your information is used for technical quotation purposes only and will never be shared.