Hydrostatic Level measurement Deltapilot FMB51

Hydrostatic Level measurement Deltapilot FMB51 – Pressure sensor with the Contite measuring cell for hydrostatic level measurement

 

Facebook
Twitter
LinkedIn

Specifications:

Measuring PrincipleHydrostatic pressure
CharacteristicPressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences; Rod version
Supply Voltage4...20 mA HART: 10,5...45 VDC (Non Ex); Ex ia: 10,5...30 VDC; PROFIBUS PA: 9...32 VDC (Non Ex); FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Reference AccuracyStandard 0.2 %; Optional 0.1 %
Long Term Stability0.05 % of URL/year
Process Temperature-10°C...85°C (14°F…212°F)
Ambient Temperature-40°C...85°C (-40°F...185°F)
Measuring Cell100 mbar...10 bar (1.5 psi...150 psi)
Smallest Calibratable Span10 mbar (1.45 psi)
Vacuum Resistance0 mbar abs.
Max. Turn Down100:1
Max. Overpressure Limit40 bar (600 psi)
Process ConnectionThread: G1 1/2, MNPT1 1/2; Flange: DN40...DN100, ASME 2"...4", JIS 10K
Material Process Membrane316L, AlloyC, Gold-Rhodium
Material GasketViton, EPDM, Kalrez, none
Fill FluidInert oil, Synthetic oil
Material Housing316L, Die-cast aluminum
Communication4...20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety ApprovalsOverfill protection WHG; SIL
Design ApprovalsEN10204-3.1; NACE MR0175
Drinking Water ApprovalsKTW/ NSF
SpecialitiesModularity to differential pressure and process pressure devices (replacable display, universal electronics); Diagnostic functions

 

 

Field of application

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

For level measurement.

  • Process connections: Threads and flanges

  • Temperature: -10 to +85°C (14°F…185° F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval

 

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

 