pressure transmitter shop
PDS843 Differential Pressure Transmitter
shop
pressure transmitter shop
PDS843 Differential Pressure Transmitter
shop



The PDS843 Differential Pressure Transmitter is a smart DP transmitter designed for measuring differential pressure and flow of liquids, gases, and steam. It converts the measured differential pressure into 4–20 mA DC with HART communication, or optional PROFIBUS PA and FOUNDATION Fieldbus FF output signals.
With ±0.04% FS accuracy, 90 ms response time, 100:1 rangeability, and long-term stability of ±0.1% FS over 10 years, the PDS843 is suitable for flow measurement, filter differential pressure monitoring, process pressure difference measurement, and industrial automation control loops.
The PDS843 differential pressure transmitter is used to measure the pressure difference between two process points. It can be applied to liquids, gases, and steam, and is commonly used in industrial applications where differential pressure needs to be converted into a stable electrical signal.
In practical process measurement, the PDS843 can be used not only for differential pressure measurement, but also for flow measurement when installed with primary elements such as orifice plates, venturi tubes, flow nozzles, or other differential pressure flow devices.
The transmitter supports 4–20 mA DC with HART communication, PROFIBUS PA, and FOUNDATION Fieldbus FF outputs. Through communication devices or fieldbus systems, users can perform remote configuration, monitoring, diagnostics, simulation, and maintenance.
The PDS843 smart differential pressure transmitter supports multiple communication options for different automation systems.
| Output / Communication | Description |
|---|---|
| 4–20 mA DC + HART | Standard analog output with HART digital communication |
| PROFIBUS PA | Digital fieldbus communication for process automation systems |
| FOUNDATION Fieldbus FF | Fieldbus communication for advanced field instrument networks |
For most industrial DP transmitter applications, 4–20 mA with HART is widely selected because it is compatible with PLC and DCS systems while still allowing smart configuration and diagnostic functions.
The PDS843 provides ±0.04% FS accuracy, supporting stable measurement for differential pressure, flow, filter monitoring, and process control applications.
With a response time of 90 ms, the transmitter can quickly respond to process changes, helping improve control loop feedback and monitoring performance.
The maximum rangeability of 100:1 allows flexible span adjustment across different working conditions. This is useful for projects where the actual calibrated differential pressure range may be much smaller than the maximum sensor range.
The transmitter offers long-term stability of ±0.1% FS over 10 years, helping reduce recalibration frequency and maintenance workload in continuous industrial operation.
The PDS843 supports smart diagnostic and simulation functions. These features help users check transmitter status, verify loop output, detect abnormal conditions, and simplify commissioning or troubleshooting.
Configuration can be performed through HART communication tools, PROFIBUS PA systems, FOUNDATION Fieldbus systems, or compatible communication devices depending on the selected output.
Different wetted materials can be selected for corrosive or chemically demanding applications. Material selection should be confirmed according to the process medium, temperature, pressure, and corrosion characteristics.
| Item | Specification |
|---|---|
| Product Name | PDS843 Differential Pressure Transmitter |
| Product Type | Smart Differential Pressure Transmitter |
| Measured Media | Liquid, Gas, Steam |
| Measurement Type | Differential Pressure / Flow |
| Output Signal | 4–20 mA DC + HART, PROFIBUS PA, FOUNDATION Fieldbus FF |
| Accuracy | ±0.04% FS |
| Response Time | 90 ms |
| Maximum Rangeability | 100:1 |
| Long-Term Stability | ±0.1% FS / 10 years |
| Configuration | HART communicator / fieldbus communication device |
| Main Functions | DP measurement, flow measurement, signal output, remote setting, monitoring, diagnostics |
The PDS843 smart DP transmitter can be used for multiple measurement tasks in industrial process systems.
Used to measure pressure difference between two points in pipelines, vessels, filters, heat exchangers, pumps, fans, and process equipment.
When used with an orifice plate, venturi tube, flow nozzle, or other primary flow element, the PDS843 can measure differential pressure and provide a signal for flow calculation in liquid, gas, or steam lines.
Used to monitor pressure drop across filters, strainers, bag filters, membrane systems, and dust collectors. Increasing differential pressure can indicate clogging, fouling, or maintenance requirements.
Applied where pressure balance, pressure loss, or pressure difference between two process points needs to be monitored for safety, efficiency, or control.
Used for differential pressure monitoring in reactors, pipelines, distillation columns, filters, separators, pumps, and process units. For corrosive media, suitable diaphragm and process connection materials should be selected.
Applied in oil and gas pipelines, gas processing systems, pressure control skids, separators, filter systems, and differential pressure flow measurement loops.
Suitable for steam flow measurement, boiler auxiliary systems, feedwater systems, condensate lines, turbine auxiliary systems, and differential pressure monitoring in power plants.
Used in water filtration, membrane systems, pumping stations, desalination equipment, wastewater treatment, and filter pressure drop monitoring.
Can be used for pressure difference monitoring in air handling units, duct systems, filter sections, fan systems, and ventilation control applications when the selected range is suitable.
Suitable for PLC/DCS systems requiring 4–20 mA HART, PROFIBUS PA, or FOUNDATION Fieldbus FF signals for process monitoring and control.
When selecting a PDS843 differential pressure transmitter, the following details should be confirmed:
Depending on the application, the PDS843 differential pressure transmitter may be used with different accessories:
For flow measurement, the transmitter should be matched with a suitable primary element such as an orifice plate, venturi tube, flow nozzle, or pitot tube, depending on the process conditions and measurement requirement.
SIYelectric supplies PDS843 differential pressure transmitters for industrial projects, replacement orders, and process instrumentation procurement. We can help check model codes, review datasheets, confirm technical specifications, match installation accessories, and prepare quotations based on actual operating conditions.
For accurate quotation, please provide:
SIYelectric can also support related DP transmitter accessories such as 3-valve manifolds, 5-valve manifolds, mounting brackets, impulse tubing, fittings, condensate pots, cooling elements, explosion-proof cable glands, and gaskets.
Available documents may include technical datasheet, certificate of conformity, inspection report, packing list, and commercial invoice, depending on the project and order requirements.
Request Your Custom Solution & Factory Price
*We respect your privacy. Your information is used for technical quotation purposes only and will never be shared.
We use cookies to improve your experience and analyze site traffic. Choose which cookies you allow.
Required for the website to function. Cannot be disabled.
Help us understand how visitors interact with the website.
Used to deliver relevant advertisements and track campaigns.
Remember your settings and preferences for a better experience.